{"id":3152,"date":"2016-11-29T19:42:05","date_gmt":"2016-11-29T19:42:05","guid":{"rendered":"https:\/\/www.geoptik.com\/?product=biological-microscope"},"modified":"2021-06-28T15:16:12","modified_gmt":"2021-06-28T15:16:12","slug":"biological-microscope-2","status":"publish","type":"product","link":"https:\/\/www.geoptik.com\/en\/prodotto\/biological-microscope-2\/","title":{"rendered":"Biological microscope"},"content":{"rendered":"<div class=\"ui-tabs-panel ui-widget-content ui-corner-bottom\" id=\"product_description\" itemprop=\"description\">\n<p>\n\t\t<span style=\"color:#0000ff;\"><strong>Illuminator:<\/strong><\/span><\/p>\n<p>\n\t\t<span id=\"result_box\" lang=\"en\"><span class=\"hps\">White LED<\/span> <span class=\"hps\">illumination<\/span> <span class=\"hps\">light source<\/span>.<br \/>\n\t\t<span class=\"hps\">Brightness control<\/span> <span class=\"hps\">via<\/span> <span class=\"hps\">a rheostat<\/span> <span class=\"hps\">located on the<\/span> <span class=\"hps\">left of the base<\/span> <span class=\"hps\">of the stand.<\/span><br \/>\n\t\t<span class=\"hps\">Power<\/span> <span class=\"hps\">LED<\/span>: <span class=\"hps\">1W<\/span>. <span class=\"hps\">Color Temperature<\/span>: <span class=\"hps\">6300K<\/span><br \/>\n\t\t<span class=\"hps\">Average life of<\/span> <span class=\"hps\">LEDs<\/span> <span class=\"hps\">around 50,000<\/span> <span class=\"hps\">hours.<\/span><br \/>\n\t\t<span class=\"hps\">Power<\/span>: <span class=\"hps\">External Power Supply 100\/240VAC<\/span>, <span class=\"hps\">50\/60Hz<\/span>, <span class=\"hps\">output<\/span> <span class=\"hps\">5Vdc<\/span> <span class=\"hps\">500mA<\/span>.<\/span><\/p>\n<p>\t\t<span id=\"result_box\" lang=\"en\"><span style=\"color:#0000ff;\"><strong><span class=\"hps\">Focus<\/span>er :<\/strong><\/span><br \/>\n\t\t<span class=\"hps\">Macro and<\/span> <span class=\"hps\">micrometric<\/span> <span class=\"hps\">focusing<\/span> <span class=\"hps atn\">(<\/span>graduated, <span class=\"hps\">0.002mm<\/span>) <span class=\"hps\">with<\/span> <span class=\"hps\">coaxial<\/span> <span class=\"hps\">locking device<\/span> <span class=\"hps\">for<\/span><br \/>\n\t\t<span class=\"hps\">prevent contact<\/span> <span class=\"hps\">between the lens<\/span> <span class=\"hps\">and the sample<\/span>.<br \/>\n\t\t<span class=\"hps\">A<\/span><span class=\"hps\">djustable focus<\/span> <span class=\"hps\">knobs<\/span>.<\/span><\/p>\n<p>\n\t\t<span style=\"color:#ff0000;\"><strong>ALC<\/strong> &#8211; Automatic light control: the level of light&nbsp;is adjusted by the microscope in order&nbsp;to maintain the same level as the one&nbsp;the user has chosen, no matter if the&nbsp;aperture of the diaphragm changes,&nbsp;another objective is inserted, opacity of&nbsp;the sample changes<\/span><\/p>\n<p>\n\t\t<br \/>\n\t\t<span lang=\"en\"><span style=\"color:#0000ff;\"><strong>Eyepieces :<\/strong><\/span><br \/>\n\t\tWA 10x\/18 mm<\/span><\/p>\n<p>\t\t<span style=\"color:#0000ff;\"><strong>Magnification :<\/strong><\/span><br \/>\n\t\t40x, 100x, 400x, 1000x<\/p>\n<p>\t\t<span id=\"result_box\" lang=\"en\"><span style=\"color:#0000ff;\"><strong><span class=\"hps\">Mechanical stage<\/span> <\/strong><span class=\"hps\"><strong>:<\/strong><\/span><\/span><br \/>\n\t\tW<\/span><span id=\"result_box\" lang=\"en\"><span class=\"hps\">ith<\/span> <span class=\"hps\">double-layer<\/span> <span class=\"hps\">sliding<\/span> <span class=\"hps\">shifter<\/span><span>,<\/span> <span class=\"hps\">size<\/span> <span class=\"hps\">125x116mm<\/span><span>, range<\/span> <span class=\"hps\">of translation<\/span><br \/>\n\t\t<span class=\"hps\">76&#215;30<\/span> <span class=\"hps\">with<\/span> <span class=\"hps\">speciment clamps<\/span> <span class=\"hps\">to accommodate<\/span> <span class=\"hps\">a glass slide<\/span><span>.<\/span><br \/>\n\t\t<span class=\"hps\">Vernier<\/span> <span class=\"hps\">scale<\/span> <span class=\"hps\">of translation<\/span> <span class=\"hps\">is available<\/span> <span class=\"hps\">on the two<\/span> <span class=\"hps\">axes<\/span> <span class=\"hps\">with precision<\/span> <span class=\"hps\">0.1 mm<\/span><\/span><\/p>\n<p>\t\t<span id=\"result_box\" lang=\"en\"><span style=\"color:#0000ff;\"><strong><span class=\"hps\">Nosepiece<\/span>:<\/strong><\/span><br \/>\n\t\t<span class=\"hps\">revolver<\/span> <span class=\"hps\">four times<\/span>, with rotation <span class=\"hps\">on ball bearings<\/span>.<\/span><\/p>\n<p>\t\t<span style=\"color:#0000ff;\"><strong>Head :<\/strong><\/span><br \/>\n\t\t<span id=\"result_box\" lang=\"en\"><span class=\"hps\">Binonocular<\/span> <span class=\"hps\">viewing<\/span> <span class=\"hps\">head<\/span>, inclined <span class=\"hps\">at 30<\/span> <span class=\"hps\">\u00b0 and<\/span> <span class=\"hps\">360 \u00b0 rotating<\/span><\/span><\/p>\n<p>\t\t<span id=\"result_box\" lang=\"en\"><span class=\"hps\"><span style=\"color:#0000ff;\"><strong>Objectives :<\/strong><\/span><br \/>\n\t\tStandard optics<\/span> <span class=\"hps\">with<\/span> <span class=\"hps\">achromatic<\/span> <span class=\"hps\">objectives<\/span> <span class=\"hps\">mechanical tube<\/span> <span class=\"hps\">length<\/span> <span class=\"hps\">160 mm<\/span>, <span class=\"hps\">composed of the following<\/span> <span class=\"hps\">objectives<\/span>:<br \/>\n\t\t<span class=\"hps atn\">[<\/span>the set <span class=\"hps\">depends on the<\/span> <span class=\"hps\">chosen model<\/span>]<br \/>\n\t\t<span class=\"hps\">-)<\/span> <span class=\"hps\">Achromatic<\/span> <span class=\"hps\">DIN<\/span> <span class=\"hps\">4X<\/span>, <span class=\"hps\">A.N.<\/span> <span class=\"hps\">0.10,<\/span> <span class=\"hps\">W.D.<\/span> <span class=\"hps\">18<\/span> <span class=\"hps\">mm<\/span><br \/>\n\t\t<span class=\"hps\">-)<\/span> <span class=\"hps\">DIN<\/span> <span class=\"hps\">Achromatic<\/span> <span class=\"hps\">10X,<\/span> <span class=\"hps\">A.N.<\/span> <span class=\"hps\">0.25,<\/span> <span class=\"hps\">W.D.<\/span> <span class=\"hps\">7 mm<\/span><br \/>\n\t\t<span class=\"hps\">-)<\/span> <span class=\"hps\">DIN<\/span> <span class=\"hps\">Achromatic<\/span> <span class=\"hps\">40X<\/span>, <span class=\"hps\">A.N.<\/span> <span class=\"hps\">0.65,<\/span> <span class=\"hps\">W.D.<\/span> <span class=\"hps\">0.53<\/span> <span class=\"hps\">mm<\/span><br \/>\n\t\t<span class=\"hps\">-)<\/span> <span class=\"hps\">DIN<\/span> <span class=\"hps\">Achromatic<\/span> <span class=\"hps\">60X<\/span>, <span class=\"hps\">A.N.<\/span> <span class=\"hps\">0.85<\/span>, <span class=\"hps\">W.D.<\/span> <span class=\"hps\">0.45 mm<\/span><br \/>\n\t\t<span class=\"hps\">-)<\/span> <span class=\"hps\">DIN<\/span> <span class=\"hps\">Achromatic<\/span> <span class=\"hps\">100X<\/span>, <span class=\"hps\">A.N.<\/span> <span class=\"hps\">1.25,<\/span> <span class=\"hps\">W.D.<\/span> <span class=\"hps\">0.13 mm<\/span> <span class=\"hps atn\">(<\/span>oil immersion)<br \/>\n\t\t<span class=\"hps\">The optics are<\/span> <span class=\"hps\">treated with<\/span> <span class=\"hps\">an anti<\/span>-fungal.<\/span><\/p>\n<p>\t\t<span id=\"result_box\" lang=\"en\"><span style=\"color:#0000ff;\"><strong><span class=\"hps\">Condenser<\/span> :<\/strong><\/span><br \/>\n\t\t<span class=\"hps\">Abbe condenser<\/span>, <span class=\"hps\">A.N.<\/span> <span class=\"hps\">1.2<\/span> <span class=\"hps\">precentered<\/span>.<\/span><\/p>\n<p>\t\t<span id=\"result_box\" lang=\"en\"><span style=\"color:#0000ff;\"><strong><span class=\"hps\">Dimensions :<\/span><\/strong><\/span><br \/>\n\t\t<span class=\"hps\">Height<\/span>: 350 <span class=\"hps\">mm<\/span><br \/>\n\t\t<span class=\"hps\">WIDTH<\/span>: 170 <span class=\"hps\">mm<\/span><br \/>\n\t\t<span class=\"hps\">DEPTH<\/span> : 210 <span class=\"hps\">mm<\/span><br \/>\n\t\t<span class=\"hps\">WEIGHT<\/span>: 4 <span class=\"hps\">kg<\/span><\/span><\/p>\n<p>\n\t\t<span style=\"color:#0000ff;\"><strong>ACCESSORIES<\/strong><\/span><\/p>\n<p>\n\t\t<span lang=\"en\"><span class=\"hps\">M-001 Eyepiece H5x.<br \/>\n\t\tM-002.1 Eyepiece WF10x\/18mm.<br \/>\n\t\tM-003 Eyepiece WF16x\/12mm.<br \/>\n\t\tM-004 Eyepiece with micrometer WF10x\/18mm.<br \/>\n\t\tM-137 Objective Achromatic 4x\/0,10.<br \/>\n\t\tM-138 Objective Achromatic 10x\/0,25.<br \/>\n\t\tM-139 Objective Achromatic 20x\/0,40.<br \/>\n\t\tM-141 Objective Achromatic 40x\/0,65.<br \/>\n\t\tM-142 Objective Achromatic 60x\/0,80.<br \/>\n\t\tM-143 Objective Achromatic 100x\/1,25 (Oil).<\/span><\/span><\/p>\n<\/div>\n<p>\n\t&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Illuminator: White LED illumination light source. Brightness control via a rheostat located on the left of the base of the stand. Power LED: 1W. Color Temperature: 6300K Average life of LEDs around 50,000 hours. Power: External Power Supply 100\/240VAC, 50\/60Hz, output 5Vdc 500mA. Focuser : Macro and micrometric focusing (graduated, 0.002mm) with coaxial locking device [&hellip;]<\/p>\n","protected":false},"featured_media":3151,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[174],"product_tag":[],"_links":{"self":[{"href":"https:\/\/www.geoptik.com\/en\/wp-json\/wp\/v2\/product\/3152"}],"collection":[{"href":"https:\/\/www.geoptik.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.geoptik.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.geoptik.com\/en\/wp-json\/wp\/v2\/comments?post=3152"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.geoptik.com\/en\/wp-json\/wp\/v2\/media\/3151"}],"wp:attachment":[{"href":"https:\/\/www.geoptik.com\/en\/wp-json\/wp\/v2\/media?parent=3152"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.geoptik.com\/en\/wp-json\/wp\/v2\/product_cat?post=3152"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.geoptik.com\/en\/wp-json\/wp\/v2\/product_tag?post=3152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}